Sample File	C:\Users\Jake\Desktop\AIM Raw\14-8-7 Test Data.S80
Classifier Model	3080
DMA Model	3081
DMA Inner Radius(cm)	0.00937
DMA Outer Radius(cm)	0.01961
DMA Characteristic Length(cm)	0.44369
CPC Model	3775 High Flow
Reference Gas Viscosity (Pa*s)	1.83245e-005
Reference Mean Free Path (m)	6.73e-008
Reference Gas Temperature (K)	296.15
Reference Gas Pressure (kPa)	101.3
Channels/Decade	64
Multiple Charge Correction	TRUE
Nanoparticle Aggregate Mobility Analysis	FALSE
Diffusion Correction	TRUE
Gas Density	0.0012
Units	Concentration (DW)
Weight	Number
Sample #	36
Date	08/07/14
Start Time	16:15:37
Diameter Midpoint
 11.3	49971.7
 11.8	59456.2
 12.2	69196.4
 12.6	77844.2
 13.1	90558.2
 13.6	102724
 14.1	119256
 14.6	137245
 15.1	157823
 15.7	176986
 16.3	202944
 16.8	231578
 17.5	258583
 18.1	288688
 18.8	329851
 19.5	364668
 20.2	406528
 20.9	436371
 21.7	486938
 22.5	529450
 23.3	572671
 24.1	618694
 25.0	658367
 25.9	700427
 26.9	748363
 27.9	781612
 28.9	826003
 30.0	857095
 31.1	883772
 32.2	898537
 33.4	912533
 34.6	907772
 35.9	898308
 37.2	884221
 38.5	854164
 40.0	815856
 41.4	770034
 42.9	723846
 44.5	667337
 46.1	609871
 47.8	548995
 49.6	490776
 51.4	435512
 53.3	379274
 55.2	327010
 57.3	280332
 59.4	235834
 61.5	197787
 63.8	161885
 66.1	128909
 68.5	103042
 71.0	80604.5
 73.7	64610.4
 76.4	51409.7
 79.1	40031.9
 82.0	30790.7
 85.1	24198.7
 88.2	18651.3
 91.4	14365.8
 94.7	11049.3
 98.2	8245.87
101.8	6530.02
105.5	5166.35
109.4	4227.39
113.4	3395.85
117.6	2794.1
121.9	2196.76
126.3	1739.08
131.0	1486.43
135.8	1218.95
140.7	1051.9
145.9	837.324
151.2	753.537
156.8	508.413
162.5	473.295
168.5	340.821
174.7	276.034
181.1	230.861
187.7	178.45
194.6	134.965
201.7	131.208
209.1	94.3688
216.7	89.3505
224.7	96.8907
232.9	80.1495
241.4	74.7946
250.3	51.1186
259.5	55.2225
269.0	65.5014
278.8	24.7699
289.0	61.0151
299.6	26.8965
310.6	38.0511
322.0	23.2187
333.8	29.9725
346.0	21.4994
358.7	21.8892
371.8	22.9067
385.4	7.22119
399.5	11.272
414.2	17.7666
429.4	12.7439
445.1	11.0775
461.4	7.27974
478.3	9.9039
Scan Up Time(s)	120
Retrace Time(s)	15
Down Scan First	FALSE
Scans Per Sample	1
Impactor Type(cm)	0.071
Sheath Flow(lpm)	5
Aerosol Flow(lpm)	0.5
CPC Inlet Flow(lpm)	1.5
CPC Sample Flow(lpm)	0.3
Low Voltage	10.71
High Voltage	9918.9
Lower Size(nm)	11.1397
Upper Size(nm)	486.968
Density(g/cc)	1
Title	
Status Flag	Normal Scan
td(s)	2.258
tf(s)	4.51249
D50(nm)	1084.4
Median(nm)	32.522
Mean(nm)	34.3712
Geo. Mean(nm)	31.9719
Mode(nm)	33.3762
Geo. Std. Dev.	1.46679
Total Concentration(#/cm)	2.38341e+007
Comment	